
(PDF) SolarWinds Certified Professional Hybrid-Cloud-Observability-Network-Monitoring Exam and Certification Test Engine
Use Hybrid-Cloud-Observability-Network-Monitoring Exam Dumps (2025 PDF Dumps) To Have Reliable Hybrid-Cloud-Observability-Network-Monitoring Test Engine
NEW QUESTION # 72
Some of the flows received are mapping to an IP address that does not match any of the nodes being monitored. It has been verified that all flow sources are also being monitored by NPM and SNMP polling.
The known source nodes for these flows have the correct IP address. What could be causing this issue?
- A. Flows are coming from a non-primary address and the setting to match the node by another IP is turned off
- B. Source machine field in the flows is not configured and the setting to match the node by another IP is turned off
- C. Flows are IPv6 and the network monitoring does not recognize that version
- D. IP address for the node is incorrect in SNMP polling but correct in the flows
Answer: A
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
SolarWinds NTA maps flow sources to nodes by matching the IP address. If a device exports flows using a secondary IP (not the one defined as "primary" in SolarWinds), and the setting "Allow matching by other IPs" is not enabled, the flow will not map to a known node. The documentation explains:
"If flow packets are received from an IP address not designated as primary in SolarWinds, and matching by other IPs is disabled, the flow source is not linked to a node. Enable the setting to match by any device IP to resolve this issue." References:
Network Performance Monitor Administrator Guide, "Flow Source Matching and IP Address Mapping" SolarWinds NTA documentation
NEW QUESTION # 73
A probe is to be built to test connections to Office 365 from two different locations. How would this be accomplished?
- A. Create both probes on hybrid cloud observability (HCO) server and designate each location.
- B. Create two probes and assign each to an agent in one location.
- C. Create two probes and assign each to an agent in each location.
- D. Create a probe, duplicate it, and change the source agent to the agent in another location.
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To test connections from two separate locations using NetPath or similar functionality in Hybrid Cloud Observability, you need to create two probes and assign each probe to an agent at each respective location.
This allows network path and experience monitoring from the point of view of both locations.
Exact Extract from Official Guide:
"To monitor network paths from multiple locations, create a separate probe for each location and assign the probe to an agent deployed at that site."
- (Network Performance Monitor Administrator Guide, "NetPath and Probes" section) References:
Network Performance Monitor Administrator Guide, NetPath and Probes
NEW QUESTION # 74
Which two of the following effects would apply to a situation where a NetPath probe polling interval is increased to 15 minutes from the default value of 10 minutes? (Choose two.)
- A. probe is more likely to show all routes
- B. accuracy is increased
- C. accuracy is decreased
- D. probe will not complete successfully
Answer: A,C
NEW QUESTION # 75
Which two of the following standards does hybrid cloud observability use to capture flow data and CBQoS data? (Choose two.)
- A. SNMP
- B. IP Fix
- C. J-Flow
- D. Net Flow
Answer: B,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
SolarWinds Hybrid Cloud Observability (HCO) supports capturing flow data and CBQoS data using:
A). IPFIX: (IP Flow Information Export) is the IETF standard for exporting flow information, supported for both flow data and CBQoS.
C). NetFlow: Developed by Cisco, widely used for flow and CBQoS data collection.
J-Flow is primarily for flow data (from Juniper devices), and SNMP is not a flow export protocol.
The documentation states:
"NetFlow (including NetFlow v9) and IPFIX are supported for flow and CBQoS data collection. These standards provide extensive network traffic and QoS visibility within HCO." References:
Network Performance Monitor Administrator Guide, "Supported Flow and CBQoS Protocols" SolarWinds NTA Documentation
NEW QUESTION # 76
Which two of the following reasons should NetFlow data be collected on a company network? (Choose two.)
- A. diagnose slow network performance
- B. identify applications causing congestion
- C. report network link up / down instances
- D. authorize user network access
Answer: A,B
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
B). NetFlow data is commonly used to diagnose network performance issues, such as identifying sources of congestion or bottlenecks.
C). NetFlow analysis provides visibility into which applications and endpoints are consuming bandwidth and causing congestion.
User authorization and link status events are not functions of NetFlow; those are handled by other monitoring tools or features.
References:
NTA Administrator Guide: NetFlow Use Cases and Benefits
NEW QUESTION # 77
Probing interval determines how often and how long information is polled from the network path. Which two of the following statements are true regarding probing intervals? (Choose two.)
- A. Probing less frequently allows the data to update more slowly and increases data accuracy
- B. Probing more frequently allows the data to update faster but decreases data accuracy
- C. Probing less frequently allows the data to update faster but decreases data accuracy
- D. Probing more frequently allows the data to update more slowly and increases data accuracy
Answer: A,B
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
A). When you probe less frequently, updates are slower but generally more accurate since there's less overhead and less chance of missing network changes due to polling overlaps.
C). Probing more frequently results in faster updates but may slightly decrease accuracy due to increased network noise and overlapping probes.
The documentation states:
"A higher probing frequency provides faster updates in NetPath views but can reduce accuracy due to more frequent sampling. Lower frequency means slower updates but typically results in higher accuracy and less system load." References:
Network Performance Monitor Administrator Guide, "NetPath Probing Interval Best Practices" SolarWinds Success Center: "Optimizing NetPath Probing Intervals"
NEW QUESTION # 78
Which two of the following statements explain creating alerts for NBAR2 applications? (Choose two.)
- A. It is possible to combine applications and NBAR2 applications.
- B. It is not possible to combine applications and NBAR2 applications.
- C. Applications and NBAR2 applications in top applications are sorted by bytes.
- D. Applications and NBAR2 applications in top applications are sorted by bits.
Answer: A,C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Applications and NBAR2 applications in top applications are sorted by bytes: The default sorting for the "Top Applications" view, including NBAR2 apps, is by bytes.
It is possible to combine applications and NBAR2 applications: SolarWinds allows combining standard and NBAR2-classified apps for alerting and reporting purposes.
Exact Extract from Official Guide:
"Top Applications, including NBAR2, are sorted by bytes and you can combine standard and NBAR2 application data in alerts and reports."
- (Network Performance Monitor Administrator Guide, "NBAR2 Applications" section) References:
Network Performance Monitor Administrator Guide, NBAR2 Applications
NEW QUESTION # 79
The status of the interfaces for a network switch shows as "unknown" in SolarWinds' platform web console, although the node status is "up". What could be the reason?
- A. ICMP is blocked between the node and the polling engine
- B. interfaces are not managed in hybrid cloud observability (HCO)
- C. hardware sensors are disabled on the node
- D. interface details have changed on the device
Answer: D
NEW QUESTION # 80
Which two of the following tasks must be accomplished to monitor servers and connections in a load- balancing environment? (Choose two.)
- A. add Cisco Nexus device in network health / performance monitoring
- B. enable F5 iControl polling
- C. add Cisco Nexus device in network device configuration manager
- D. enable CLI polling
Answer: B,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To monitor servers and connections in a load-balancing environment-specifically for F5 BIG-IP load balancers-SolarWinds requires that you:
Enable CLI polling: This is necessary for SolarWinds to collect configuration and health data from network devices.
Enable F5 iControl polling: F5 iControl API allows SolarWinds to collect load balancer details, including virtual servers and pools, for deep monitoring of server and connection health.
Adding Cisco Nexus devices relates to switch monitoring and is not required for F5/BIG-IP load balancer server connection monitoring.
Exact Extract from Official Guide:
"To fully monitor F5 BIG-IP load balancers, enable both SNMP and CLI polling, and configure F5 iControl API credentials for device access and load balancing visibility."
- (Network Performance Monitor Administrator Guide, "Network Insight for F5 BIG-IP" section) References:
Network Performance Monitor Administrator Guide, Network Insight for F5 BIG-IP
NEW QUESTION # 81
Which two of the following actions can be taken to resolve duplicate flows? (Choose two.)
- A. Enable the flow de-duplication feature.
- B. Enable automatic addition of flow sources.
- C. Ensure NetFlow export is enabled on sub-interfaces.
- D. Ensure NetFlow is enabled for ingress interfaces.
Answer: A,D
NEW QUESTION # 82
It is noted that the hardware health monitoring for a Cisco switch is generating false positives. It is verified that the alerted hardware issues are not occurring. What is causing the issue?
- A. Modify the widget thresholds to filter out the false positives.
- B. Hardware sensors were incorrectly assigned to another switch.
- C. MIB on the device is not the preferred MIB that is being polled.
- D. Restart SNMP on the device to refresh the hardware statistics.
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
False positives in hardware health alerts often occur when the polled MIB on the device is not the preferred or correct MIB for that particular hardware platform. This can result in SolarWinds interpreting SNMP data incorrectly, causing inaccurate alerts. Ensuring that the device is using the recommended MIB for hardware health resolves these false alert issues.
Reference:
"False hardware health alerts may result from polling the incorrect or non-preferred MIB on the device.
Always verify that the correct MIB is being polled for accurate hardware monitoring."
- (Network Performance Monitor Administrator Guide, Hardware Health Monitoring section)
NEW QUESTION # 83
Which two of the following locations can hardware health be enabled? (Choose two.)
- A. list resources
- B. manage MIB
- C. asset inventory
- D. main settings
Answer: A,B
NEW QUESTION # 84
A device studio poller is being built for the node details widget. The plan is to add a field for serial numbers.
How would this be accomplished?
- A. Default widgets are being used, fields cannot be added to the device studio
- B. Create a serial number universal device poller (UDP) and link to the node details widget.
- C. Change one data source field to serial number and supply the OID for the data source.
- D. Add the object ID (OID) to an existing data source and edit the field name in the widget.
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To display the serial number in the node details widget using Device Studio, you must add a new data source field, name it "Serial Number," and provide the correct OID that polls the serial number from the device. This field then appears in the node details widget for the custom poller. Editing an existing field's name is not best practice, and UDPs cannot be linked directly to Device Studio widgets.
Reference:
Device Studio Admin Guide, "Adding Serial Number Field to Node Details Widget,"
"Create a data source with the OID for serial number and label the field accordingly in Device Studio."
NEW QUESTION # 85
Which tool in the web console will verify the object ID (OID) being used is a match for the node being created for a custom poller?
- A. firmware repository
- B. CLI settings
- C. MIB browser
- D. component library
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
The MIB browser tool in the SolarWinds web console is designed to browse, query, and verify OIDs on monitored nodes. It allows you to test if an OID returns valid data for a specific device before assigning it in a custom poller. This ensures compatibility and accuracy of your custom monitoring setup.
Reference:
Universal Device Poller Admin Guide, "Using the MIB Browser,"
"The MIB browser verifies if an OID is valid and supported on the node."
NEW QUESTION # 86
An unknown traffic event is noted in the web console. What is the likely cause?
- A. missing a byte group from flow field configurations
- B. incorrectly configured source or destination port in the flows
- C. a firewall is blocking the traffic flow configurations
- D. receiving flows from a device not monitored by the network
Answer: D
NEW QUESTION # 87
Which two of the following points can be checked when the node status is "unknown"? (Choose two.)
- A. polling method
- B. OID
- C. ping response
- D. view method
Answer: A,C
NEW QUESTION # 88
......
Hybrid-Cloud-Observability-Network-Monitoring Dumps Full Questions with Free PDF Questions to Pass: https://www.prepawayete.com/SolarWinds/Hybrid-Cloud-Observability-Network-Monitoring-practice-exam-dumps.html
Hybrid-Cloud-Observability-Network-Monitoring PDF Recently Updated Questions Dumps to Improve Exam Score: https://drive.google.com/open?id=1HcmBo9uxRVgdPLsCM55yISsVAYx0PrYY