Get 100% Passing Success With True HPE0-S60 Exam! [Dec-2024]
HP HPE0-S60 PDF Questions - Exceptional Practice To Delta - HPE Compute Solutions
HPE0-S60 certification exam consists of 40 multiple-choice questions that the candidates must complete in 1 hour and 15 minutes. HPE0-S60 exam is available in English and Japanese, and the passing score is 65%. HPE0-S60 exam fee is $150, and the exam can be taken at any Pearson VUE testing center worldwide.
HP HPE0-S60 Certification Exam is a Delta exam, which means that it is designed for individuals who already hold a HPE ATP or ASE certification. The Delta exam is intended to test the knowledge and skills of an individual in the areas that have changed since they last took the certification exam. The HP HPE0-S60 Delta exam is a 90-minute exam that consists of 40 multiple-choice questions. HPE0-S60 exam is available in English, Japanese, and Simplified Chinese.
HP HPE0-S60 (Delta - HPE Compute Solutions) certification exam is designed for individuals who want to demonstrate their knowledge and skills in designing, deploying, and managing HPE compute solutions. Delta - HPE Compute Solutions certification exam is intended for individuals who have already earned the HPE ASE - Server Solutions Architect V3 certification and want to upgrade their skills to the latest HPE compute solutions. The HPE0-S60 certification exam covers a wide range of topics, including HPE ProLiant Gen10 and Synergy server solutions, HPE OneView management solutions, HPE SimpliVity hyperconverged solutions, and HPE Composable Infrastructure solutions.
NEW QUESTION # 39
Which statement about login redistribution is true?
- A. Login redistribution is available only If HPE Primera or HPE Alletra is connected directly to the HPE Synergy frame
- B. Login redistribution is a licensed feature and the number of licenses required depends on the number of active ports
- C. Login redistribution is supported only on the HPE Synergy Virtual Connect SE 32Gb FC Modules
- D. Login redistribution is used for login balancing when they are not distributed evenly over the FC links
Answer: D
Explanation:
Login redistribution is a feature that ensures logins are balanced across available FC (Fibre Channel) links.
This process helps maintain optimal performance and redundancy by redistributing logins if they are not evenly distributed. This feature is essential in environments where maintaining balanced load distribution is critical for performance and reliability.
NEW QUESTION # 40
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives The customer requested the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- An appropriate number of vSAN Standard licenses for each compute node
- One HPE O3940 Storage Module with 40 SSDs - All required cables and options Which statement about this request is true?
- A. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
- B. vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses
- C. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
- D. vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN
Answer: D
NEW QUESTION # 41
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives The customer requested the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- An appropriate number of vSAN Standard licenses for each compute node
- One HPE O3940 Storage Module with 40 SSDs - All required cables and options Which statement about this request is true?
- A. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
- B. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
- C. vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses
- D. vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN
Answer: C
Explanation:
vSAN licenses and vSphere licenses are separate entities. While vSAN licenses cover the storage virtualization aspect of VMware's hyper-converged infrastructure, vSphere licenses are required for the actual hypervisor operations. Therefore, the customer must ensure they have the appropriate vSphere licenses in addition to vSAN licenses for their compute nodes.
NEW QUESTION # 42
An HPE Synergy customer needs to prevent a timeout and loss of communication during an external switch firmware upgrade.
Click the parameter that the customer should configure within an uplink set to meet this requirement
Answer:
Explanation:
NEW QUESTION # 43
Your customer reports mat an external FC boot volume for Windows server is visible four times in the Disk Management 1 online and 3 offline.
What should you do to resolve this issue?
- A. Disable deduplication for this volume at the array level
- B. Remove the offline disks using array management tools
- C. Remove the offline disks using Windows Disk Management
- D. Install and configure MPIO on me Windows system
Answer: D
NEW QUESTION # 44
Your customer is trying to grow a VMware duster using HPE OneView for VMware vCenter Server. They get an error and cannot proceed Which tool should you use to troubleshoot the problem?
- A. vCenter Server to verify if an OS Bund Plans property defined and has ESXi image uploaded
- B. HPE One View for VMware vCenter Server to verify if server profile template s property imported and registered
- C. ILO interlace of a given HPE Synergy compute node to verify whether this node is registered within HPE Oneview.
- D. HPE OneView interface to import an existing cluster using the hypervisor cluster profile functionality.
Answer: B
NEW QUESTION # 45
Your customer added a new Ethernet network in HPE Oneview mat is used to manage their HPE Synergy platform.
When the customer tries to connect one of the compute nodes to this network through the server profile, this network is not available.
What must be done to fix this issue?
- A. The newly created network must be added to the uplink set within the LIG, and Logical interconnect configuration must be updated from the LIG.
- B. To make this network available to use in the server profile, the customer must enable the Smart Link feature within network definition.
- C. Check within the server profile which server hardware is used and perform the Refresh operation on this compute node to get the latest adapter information.
- D. Check the Logical Enclosure settings and verify if the maximum number of networks allowed for this LE is reached.
Answer: A
NEW QUESTION # 46
Your customer plans to expand an existing nPar based on a single HPE Superdome Flex chassis. Which statement about workload availability during expansion is true?
- A. Powered nPar can be expanded if it does not use HPE Persistent Memory
- B. Powered nPar can be expanded only if HPE Superdome Flex 280 is used
- C. HPE Superdome Flex does not support expansion of powered on nPars
- D. Online expansion is available only if RMC is used for management.
Answer: A
Explanation:
HPE Superdome Flex allows for the expansion of powered-on nPars (nPartitions), but this capability is subject to certain conditions. One of these conditions is that the nPar does not use HPE Persistent Memory. Expanding an nPar with Persistent Memory typically requires a shutdown to reconfigure the memory settings safely.
NEW QUESTION # 47
Your customer plans to deploy VMware vSAN using D3940 Storage Modules.
Which statement about this solution is true?
- A. For VMware vSAN deployment, all drives in the D3940 storage modules must be SSD drives.
- B. All drives in the D3940 storage modules must formulate a single logical drive with RAID5 configured
- C. The 12Gb SAS modules required for D3940 connectivity can only be installed in the first fabric.
- D. To use the storage controller that will access D3940 storage modules, a second CPU must be installed.
Answer: C
NEW QUESTION # 48
Match each HPE OneView network type with its definition.
Answer:
Explanation:

NEW QUESTION # 49
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.
Answer:
Explanation:
NEW QUESTION # 50
Which statement about manual orchestration during the firmware update is true?
- A. It provides the ability to install an older firmware version than currently Installed In the interconnect
- B. It allows all the interconnect modules to be activated manually at the same time.
- C. It is supported only for logical enclosures with at least three frames
- D. It provides an ability to select and update one side of the Interconnect topology at a time
Answer: D
NEW QUESTION # 51
Which statement about HPE Apollo 2000 Gen10 Plus platform is true?
- A. It offers servers with AMD EPYC and Intel Xeon Scalable CPUs
- B. It is equipped with HPE Persistent memory by default
- C. It can support a single processor only and up to 4 per chassis
- D. It is fully managed using HPE OneView including all connections
Answer: C
NEW QUESTION # 52
Your customer plans to use HPE Primera to boot HPE Synergy compute nodes. They currently have two HPE Virtual Connect SE 100Gb F32 Module for Synergy modules installed in the frame. The customer wants to use FC as a storage access protocol What must be done to complete this task?
- A. Enable FC primary and secondary boot on the modules through the HPE OneView interface
- B. Enter both modules into a maintenance mode, then enable FC connectivity through CLI
- C. FC connectivity on the modules should be enabled through the service console by disabling FCoE.
- D. Add FC upgrade licenses in HPE OneView that will enable FC connectivity for the modules
Answer: D
Explanation:
To use FC (Fibre Channel) as a storage access protocol with HPE Primera to boot HPE Synergy compute nodes, you must add FC upgrade licenses in HPE OneView. These licenses enable FC connectivity for the HPE Virtual Connect SE 100Gb F32 Modules, allowing the compute nodes to connect to the FC storage.
NEW QUESTION # 53
Your customer manages HPE Synergy using HPE OneView. For one of its projects, the company purchased 50 HPE.
ProLiant DK385 Gen10 Plus v2. They plan to manage the new systems using HPE OneView as well.
What should the customer do to manage rack system using HPE OneView?
- A. add the rack system to the HPE OneView instance used to manage HPE Synergy to centralize management of all systems.
- B. Deploy an HPE OneView virtual appliance, and, after configuration, use it to manage only the rack systems.
- C. Deploy HPE OneView Global Dashboard and add the rack systems there, as AMD systems are not directly in HPE OneView.
- D. connect the rack system to an IPDU and add the IPDU to the HPE. OneView instance that is used for HPE synergy management.
Answer: B
NEW QUESTION # 54
Your customer experienced some problems caused by outdated HPE Superdome Flex firmware. Which update method should they use to avoid these issues in the future?
- A. HPE OneView method for I/O firmware update procedure
- B. RMC CLI to update I/O and HPE Persistent Memory firmware
- C. HPE OneView IT HPE Persistent Memory firmware must be updated.
- D. HPE SUM if HPE Persistent Memory firmware must be updated
Answer: B
NEW QUESTION # 55
Your customer wants to add a second HPE Synergy frame to an existing logical enclosure Based on a single HPE Synergy frame. The customer wants to use a highly available master setup.
Which procedures should De performed during the expansion process? (Select two.)
- A. Create a new logical enclosure based on both HPE Synergy frames.
- B. Modify an existing logical interconnect to include second HPE Synergy frame.
- C. Move one of the master modules to the appropriate interconnect bay in the second frame.
- D. Create a new logical interconnect group and enclosure group for two frames setup
- E. Re-parent an existing enclosure group to the new logical interconnect group.
Answer: A,B
NEW QUESTION # 56
Your customer added a new Ethernet network in HPE Oneview mat is used to manage their HPE Synergy platform.
When the customer tries to connect one of the compute nodes to this network through the server profile, this network is not available.
What must be done to fix this issue?
- A. The newly created network must be added to the uplink set within the LIG, and Logical interconnect configuration must be updated from the LIG.
- B. To make this network available to use in the server profile, the customer must enable the Smart Link feature within network definition.
- C. Check within the server profile which server hardware is used and perform the Refresh operation on this compute node to get the latest adapter information.
- D. Check the Logical Enclosure settings and verify if the maximum number of networks allowed for this LE is reached.
Answer: A
Explanation:
When a new Ethernet network is created in HPE OneView and is not available in the server profile, it is typically because the network has not been added to the uplink set within the Logical Interconnect Group (LIG). To resolve this issue, the network must be included in the uplink set configuration, and then the logical interconnect configuration must be updated from the LIG to propagate the changes.
NEW QUESTION # 57
Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames How will this change impact the customer environment?
- A. The customer has to create a new management ring for new logical enclosure because the maximum number of frames m a single management ring is reached.
- B. The customer can add a new logical enclosure to an existing setup once all required licenses are addedtoHPE OneView and associated with the new frames.
- C. The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.
- D. The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.
Answer: A
Explanation:
HPE Synergy management rings have a maximum capacity for the number of frames they can manage. With
18 frames already managed in 6 logical enclosures, adding 5 more frames would exceed this capacity.
Therefore, the customer needs to create a new management ring for the new logical enclosure to ensure proper management and operation.
NEW QUESTION # 58
......
HPE0-S60 dumps - PrepAwayETE - 100% Passing Guarantee: https://www.prepawayete.com/HP/HPE0-S60-practice-exam-dumps.html
Fast, Hands-On HPE0-S60 exam: https://drive.google.com/open?id=1EtCjEmHwcwwP2oslsAy4FuPqFoAHxwa_